Oh. That means my steam requirement would be 1040kW * 3600 / (latent heat of steam at heating coil outlet = 2226.23kJ/kg); which would reduce...
Yes; There will be a steam condenser in the system.
I think i might have gotten a formula wrong; My total heat requirement - 620kW (heating up) + 420kW (heat loss) = 1040kW Steam Enthalpy at...
Hi all, Im currently doing a barge design carrying palm oil and currently having problems with the steam boiler capacity. The requirements calls...